| More Power. Smaller Footprint. |
|
 |
|
| Power your business with our new compact range of generator sets 7.5 KVA & 10 KVA |
| |
| 7.5 KVA and 10 KVA Diesel Generator set |
Best in class, the new range of generator sets are: Compact with a smaller foot print, Efficient in performance, Quiet with low noise level, easy to service and deliver reliable power.
This series of generator sets offers selectable motor starting capacity with a choice of alternator sizes. PowerStart 0500™ or PowerCommand® 1.1™ is offered as standard for total system integration. Product benefits include best in class fuel economy, easily accessible service points and extended service intervals.
The product also boasts best in class enclosed solutions across the product range including single point lifting capability as standard. Acoustic, fire retardant enclosure linings provide quality, world leading performance; pushing the boundaries of technology to provide higher ambient capabilities whilst maintaining its compact size.
|
| |
| Product Features - 7.5 & 10 KVA |
| |
| Engine |
|
|
|
Control Panel |
|
| |
|
|
|
|
|
Cummins ‘DXP Series’ diesel generator sets are powered by Cummins‘ X Series” engines, rated at 1500 RPM and conforming to ISO 8528 specifications. The engines are radiator water cooled, four stroke and multi-cylinder, conforming to BS 5514 or ISO 14396. |
|
 |
|
| The control panel is manufactured with 14/16 gauge CRCA sheet and is power coated for weather-proof, long lasting finish. It comprises of: |
| Standard engine instrumentation with PS 0500TM control panel that measures: |
-Individual phase current (Amps)
-Phase Voltage (V)
-Generator output frequency
-Lube Oil pressure (kpa) |
MCB of suitable rating
Starter with push button
Current transformers
Instrument fuses duly wired ferruled
|
| |
|
 |
|
| |
|
| Alternator |
| |
The alternator from Cummins Generator Technologies, is suitable for operation at 1500 RPM, 415 volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system. The 1.0 pf is suitable for 50 Hz, 1 phase, 2 wire system conforming to BS 5000 / IS 4722. The alternator is brushless type, screen protected, revolving field, self excited and regulated through an AVR. The alternator comes with the following features:
• +_1.0% Voltage regulation (max.) in static conditions
• IP:23 Enclosure |
|
 |
| |
|
| |
| Enclosures |
The 7.5 & 10 kVA series engine powered generator set comes with a sound attenuated enclosure to cover and protect the generator set. The sound attenuated enclosures are made of 2 mm thick Cold Rolled (CRCA) sheets and are mounted on a structural sheet metal base frame for exceptional durability. The walls of the enclosure are insulated with fire retardant foam so as to comply with the CPCB norms. Enclosures are designed to optimize generator set cooling performance, providing you with confidence that generator set ratings and ambient capability have not been compromised.
|
| Totally Eco-friendly |
| Product Lifecycle costs |
Service support and spare parts
|
 |
| |
 |
| |
| Typical enclosed genset dimensions |
| Genset Model |
Rating (kVA ) |
Length (mm) |
Width (mm) |
Height (mm) |
Weight (kgs) |
Std. Fuel Tank Capacity (Ltrs) |
| C 7.5 D5 (1) |
7.5 |
1456 |
847 |
1032 |
575 |
100 |
| C 7.5 D5 (3) |
7.5 |
1456 |
847 |
1032 |
575 |
100 |
| C 10 D5 (1 Phase) |
10 |
1456 |
847 |
1032 |
575 |
100 |
| C 10 D5 (3 Phase) |
10 |
1456 |
847 |
1032 |
575 |
100 |
|
| |
| |
Techincal Data
|
Generator set specifications |
| Model |
C 7.5 D5 |
C 10 D5 |
| Prime Power Rating kVA / kW |
1 phase - 7.5/7.5 & 3 phase - 7.5/6 |
1 phase - 9.2/9.2 & 3 phase - 10/8 |
| Current (Amps) |
1 phase - 26 & 3 phase - 10.5 |
1 phase - 34.78 & 3 phase - 14 |
| Power Factor |
1 phase - 1.0 & 3 phase - 0.8 (lag) |
1 phase - 1.0 & 3 phase - 0.8 (lag) |
| No. of Phases |
1 Phase/ 3 Phase |
1 Phase/ 3 Phase |
|
|
| |
Engine specifications |
| Make |
Cummins |
Cummins |
| Model
|
X 1.3 G2 |
X 1.3 G2
|
| BHP |
15.78
|
15.78 |
| Cooling |
Water Cooled |
Water Cooled |
| Aspiration |
Natural |
Natural |
| No. of Cylinders |
2 |
2 |
| RPM |
1500 |
1500 |
| Bore (mm) x Stroke (mm) |
95 x 91 |
95 x 91 |
| Compression Ratio |
18.1 (+ 0.3):1 |
18.1 (+ 0.3):1 |
| Displacement (Ltrs.) |
1.29 |
1.29 |
| Fuel |
HSD |
HSD |
| Fuel Consumption (Ltr/hr) @ 75% Load with Radiator & Fan |
2.4 |
2.7 |
| Governor |
Electronic |
Electronic |
| Starting System |
12 V Electrical |
12 V Electrical |
| Lube oil Specification |
CH4 15W40 |
CH4 15W40 |
| Lube oil Sump Capacity (Ltrs.) |
4 |
4 |
| Lube oil consumption (LPH) |
0.3% of fuel consumption |
0.3% of fuel consumption |
| Total Coolant Capacity (Ltrs.) |
4.65 |
4.65 |
| Exhaust Pipe Size (mm) |
34.1 |
34.1 |
| Battery Capacity / Rating |
32 Ah 12 V |
32 Ah 12 V |
|
|
| |
| Alternator specifications |
| Make (Brand) |
CGT (Stamford) |
CGT (Stamford) |
| Enclosure
|
IP 23 |
IP 23 |
| Voltage Regulation (Max.) |
+/- 1% |
+/- 1% |
| Class of Insulation |
H Class |
H Class |
| RPM / Frequency |
1500 / 50 Hz |
1500 / 50 Hz |
| Power Factor |
0.8 (lag) |
0.8 (lag) |
| No. of Phases |
3 Phase |
1 Phase |
3 Phase |
1 Phase
PI |
| Frame Size |
PI 044 D |
PI 044 F |
PI 044 E |
044 G |
| Voltage |
415 V |
230 V |
415 V |
230 V |
| Recommended Cable size sq. mm. x No. of Runs (Allum. Armoured AYFY 3 1/2 Core) |
6 x 1 |
35 x 1
|
10 x 1 |
50 x 1
|
|
| |
| Conformance standards |
| IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046 |
| |
| |
| |
|
| |
 |